Change Log#

v2.9.3 - September 2025#

  • * ADDED: The LINUS6.4 App can now Save & Load Snapshots on LINUS6.4

  • * ADDED: The App now allows changing the subnet mask in the network settings

  • * ADDED: Verify and test Fallback routing by switching between Digital & Analog:

    LINUS Control and the LINUS6.4 App now keep analog and fallback routing identical when switching input type.

  • FIXED: In rare cases, the State could be too large to be saved on the network

  • FIXED: LINUS6.4 firmware v3.00 would not restore Bridge mode on channels 3+4 correctly when booting

Product

Firmware Version

LINUS6.4

V3.10

LINUS14 / LINUS14-D

V3.70

LINUS12C

V3.71

LINUS10

V2.70

LINUS10-C

V5.70

LINUS5-C

V5.70

LINUS CON

V1.70

v2.9.2 - August 2025#

  • * ADDED: The new LINUS6.4 App offers wireless control over the amplifier from any mobile device

  • * ADDED: Save Project Notes and information about the Show and Venue in your LINUS Control project file

  • ADDED: Routing: Patch / Unpatch Columns using Shift

  • FIXED: Workspace: When adding a Group, the name no longer gets overwritten by default text

  • FIXED: Workspace: It is no longer possible to “Identify” offline amps

  • FIXED: LINUS6.4: The display would stay black on reboot in rare occasions if all input routing was unpatched

  • CHANGED: Routing: Analog & Fallback Routing stay constant when switching between Analog and Digital inputs

  • CHANGED: Amps Page: Lock icons changed for clarity

  • CHANGED: Tuning: Add second decimal place to Delay field, for improved precision

  • CHANGED: LINUS6.4: New Limiter DSP architecture for more transparent operation

Product

Firmware Version

LINUS6.4

V3.00

LINUS14 / LINUS14-D

V3.70

LINUS12C

V3.71

LINUS10

V2.70

LINUS10-C

V5.70

LINUS5-C

V5.70

LINUS CON

V1.70

v2.9.1 - May 2025#

  • ADDED: LINUS6.4: N-RAY and KTV Soundbar speakers are now available for the LINUS6.4

  • ADDED: Workspace: Bridged Icon at loudspeaker banner is shown if a bridged preset is selected for LINUS6.4

  • FIXED: LINUS6.4: Prevent processor freeze at quick reboot

  • FIXED: LINUS6.4: AES clock lock improvements

  • CHANGED: LINUS6.4: Updated limiter performance

  • CHANGED: LINUS6.4: Highpass at 10Hz to avoid triggering DC Protect

  • CHANGED: LINUS6.4: “DC Error” shown in display when there is a fault condition

Product

Firmware Version

LINUS6.4

V2.50

LINUS14 / LINUS14-D

V3.70

LINUS12C

V3.71

LINUS10

V2.70

LINUS10-C

V5.70

LINUS5-C

V5.70

LINUS CON

V1.70

v2.9 - March 2025#

  • * ADDED: Global Standby: Amplifiers which are suited with the standby feature can now be switched globally into standby or woken up. This feature is located in the “AMPS” view.

  • ADDED: LINUS6.4: Display: Indicate Power Off while device is shutting down

  • FIXED: LINUS Control is now fully compatible with the Windows 11 Version 24H2

  • FIXED: LINUS12C: Device MAC address stays constant between reboots

  • FIXED: LINUS6.4: Fix firmware hangup that could occur in rare cases

  • FIXED: LINUS6.4: Display: Fix text overlapping icons

  • CHANGED: Limiter meter indication of modules and in monitor view has been improved.

    Logic for modules:
    Gain reduction under 3dB no visual indication
    Gain reduction over 3dB orange meter indication
    Logic for monitor view:
    Gain reduction always indicated in orange and with improved scale
  • CHANGED: LINUS6.4: All speaker settings for LINUS6.4 have optimised limiter operation which ensure best system performance and protection

  • CHANGED: LINUS6.4: Display: Limiter meters show orange when gain reduction is ≥ 3dB and red when gain reduction reaches 10dB

Product

Firmware Version

LINUS6.4

V1.80

LINUS14 / LINUS14-D

V3.70

LINUS12C

V3.71

LINUS10

V2.70

LINUS10-C

V5.70

LINUS5-C

V5.70

LINUS CON

V1.70