Change Log#
v2.9.3 - September 2025#
* ADDED: The LINUS6.4 App can now Save & Load Snapshots on LINUS6.4
* ADDED: The App now allows changing the subnet mask in the network settings
* ADDED: Verify and test Fallback routing by switching between Digital & Analog:
LINUS Control and the LINUS6.4 App now keep analog and fallback routing identical when switching input type.
FIXED: In rare cases, the State could be too large to be saved on the network
FIXED: LINUS6.4 firmware v3.00 would not restore Bridge mode on channels 3+4 correctly when booting
Product |
Firmware Version |
|---|---|
LINUS6.4 |
V3.10 |
LINUS14 / LINUS14-D |
V3.70 |
LINUS12C |
V3.71 |
LINUS10 |
V2.70 |
LINUS10-C |
V5.70 |
LINUS5-C |
V5.70 |
LINUS CON |
V1.70 |
v2.9.2 - August 2025#
* ADDED: The new LINUS6.4 App offers wireless control over the amplifier from any mobile device
* ADDED: Save Project Notes and information about the Show and Venue in your LINUS Control project file
ADDED: Routing: Patch / Unpatch Columns using Shift
FIXED: Workspace: When adding a Group, the name no longer gets overwritten by default text
FIXED: Workspace: It is no longer possible to “Identify” offline amps
FIXED: LINUS6.4: The display would stay black on reboot in rare occasions if all input routing was unpatched
CHANGED: Routing: Analog & Fallback Routing stay constant when switching between Analog and Digital inputs
CHANGED: Amps Page: Lock icons changed for clarity
CHANGED: Tuning: Add second decimal place to Delay field, for improved precision
CHANGED: LINUS6.4: New Limiter DSP architecture for more transparent operation
Product |
Firmware Version |
|---|---|
LINUS6.4 |
V3.00 |
LINUS14 / LINUS14-D |
V3.70 |
LINUS12C |
V3.71 |
LINUS10 |
V2.70 |
LINUS10-C |
V5.70 |
LINUS5-C |
V5.70 |
LINUS CON |
V1.70 |
v2.9.1 - May 2025#
ADDED: LINUS6.4: N-RAY and KTV Soundbar speakers are now available for the LINUS6.4
ADDED: Workspace: Bridged Icon at loudspeaker banner is shown if a bridged preset is selected for LINUS6.4
FIXED: LINUS6.4: Prevent processor freeze at quick reboot
FIXED: LINUS6.4: AES clock lock improvements
CHANGED: LINUS6.4: Updated limiter performance
CHANGED: LINUS6.4: Highpass at 10Hz to avoid triggering DC Protect
CHANGED: LINUS6.4: “DC Error” shown in display when there is a fault condition
Product |
Firmware Version |
|---|---|
LINUS6.4 |
V2.50 |
LINUS14 / LINUS14-D |
V3.70 |
LINUS12C |
V3.71 |
LINUS10 |
V2.70 |
LINUS10-C |
V5.70 |
LINUS5-C |
V5.70 |
LINUS CON |
V1.70 |
v2.9 - March 2025#
* ADDED: Global Standby: Amplifiers which are suited with the standby feature can now be switched globally into standby or woken up. This feature is located in the “AMPS” view.
ADDED: LINUS6.4: Display: Indicate Power Off while device is shutting down
FIXED: LINUS Control is now fully compatible with the Windows 11 Version 24H2
FIXED: LINUS12C: Device MAC address stays constant between reboots
FIXED: LINUS6.4: Fix firmware hangup that could occur in rare cases
FIXED: LINUS6.4: Display: Fix text overlapping icons
CHANGED: Limiter meter indication of modules and in monitor view has been improved.
Logic for modules:Gain reduction under 3dB no visual indicationGain reduction over 3dB orange meter indicationLogic for monitor view:Gain reduction always indicated in orange and with improved scaleCHANGED: LINUS6.4: All speaker settings for LINUS6.4 have optimised limiter operation which ensure best system performance and protection
CHANGED: LINUS6.4: Display: Limiter meters show orange when gain reduction is ≥ 3dB and red when gain reduction reaches 10dB
Product |
Firmware Version |
|---|---|
LINUS6.4 |
V1.80 |
LINUS14 / LINUS14-D |
V3.70 |
LINUS12C |
V3.71 |
LINUS10 |
V2.70 |
LINUS10-C |
V5.70 |
LINUS5-C |
V5.70 |
LINUS CON |